40mbcq12

Wireless Remote Controller included with indoor unit Optional Wired Remote Controller (Timer Function) Wired Remote Controller KSACN0501AAA (7 Day programmable) included

40mbcq12. High Wall Heat Pump Ductless System Indoor Model: Job Data: Location: Buyer: Buyer P.O. #: Carrier #: Unit Number: Model Number: Date: 12 Face Area Sq. Ft. 2.19

Versatile Comfort You Can Look Up To. Ideal for a converted space or room addition where ductwork is not available, the Preferred™ Series 40MBCQ Cassette fits comfortably over-head to deliver quiet, unobtrusive heating and cooling. It senses the temperature at your handheld remote to place comfort where you need it most, and provides the ...

48,000 BTU 22.4 SEER 5-Zone Heat Pump System 9+9+12+12+12 - Casette. F7ADFDF7-0815-40AD-8F6D-5E584C00AAA8. Out of StockModes: Cool, Heat, Dry, Fan, Auto. Auto-restart function louver control (fixed or swing) Three fan speeds. Outside air intake. Built-in condensate lift pump. Follow Me (senses temperature at handheld remote) Heating Setback (46° F Heating Mode) Aluminum Golden Hydrophilic pre-coated fins. Available in 208/230V.The document listing is represented by a combination of the UL CCN and File Number. A UL CCN (Category Control Number) is the code that represents the Product Category (Category Description).Connect a dry nitrogen cylinder and regulator to the system and break vacuum until the system reaches 2 psig. Close the service valve and allow the system to stand for one hour. During this time, the dry nitrogen can diffuse throughout the system absorbing moisture. Pump the system down to 1000 microns.Indoor Units. 12K HP FCU CASSETTE 208/230-1 PERFORMANCE. 12K HP FCU CASSETTE 208/230-1 PERFORMANCE. 40MBCQ12---3. Out of Stock. Availability: Available for Delivery. Category: Ductless Indoor Cassette. Warehouse Availability: AVON, MALD. CFM: 280, 400.

Connect a dry nitrogen cylinder and regulator to the system and break vacuum until the system reaches 2 psig. Close the service valve and allow the system to stand for one hour. During this time, the dry nitrogen can diffuse throughout the system absorbing moisture. Pump the system down to 1000 microns."The risks were right under the noses of the Fed," the Muddy Waters Research founder told Bloomberg about the turmoil that hit US regional banks. Jump to The Federal Reserve fueled...38maqb09r--3 38maqb12r--3 38maqb18r--3 38maqb24r--3 38maqb30r--3 38maqb36r--3 38mbrq36a--3 38mbrq48a--3 38mbrq58a--3 ffmanp019t00 ffmanp025t0038mhrc09a--1 38mhrc12a--1 38mhrc09a--3 38mhrc12a--3 38mhrc18a--3 38mhrc24a--3 38mhrbc12aa1 38mhrbc12aa3 38mhrbc18aa3 38mhrbc24aa3 40mhhc09---1

40MBCQ12---3 2 Voltage, Phase, Cycle V/Ph/Hz 208/230-1-60 19 4 MCA A. 0.2 Body Unit Width in (mm) 22.44 (570) Standard Body Unit Height in (mm) 10.24 (260) Optional Body Unit Depth in (mm) 22.44 (570) Cooling Indoor DB Min -Max °F(°C) 63~90 (17~32) Body Net Weight lbs (kg) 35.27 (16)PERFORMANCE™ SERIES 38MA*R OUTDOOR UNITS SPECIFICATIONS: 38MA*R Outdoor Unit Heat Pump System Size 12 9 12 18 24 30 36 Outdoor Model 38MAQB12R--1 38MAQB09R--3 38MAQB12R--3 38MAQB18R--3 38MAQB24R--3 38MAQB30R--3 38MAQB36R--338mhrc09a--1 38mhrc12a--1 38mhrc09a--3 38mhrc12a--3 38mhrc18a--3 38mhrc24a--3 38mhrbc12aa1 38mhrbc12aa3 38mhrbc18aa3 38mhrbc24aa3 40mhhc09---1DRILL A HOLE IN THE WALL FOR THE INTERCONNECTING PIPING, DRAIN AND WIRING. For maximum serviceability, it is recommended that you have the refrigerant line, flare connection and the drain connection on the outside of the wall so the fan coil can be mounted. Determine the pipe hole position. Drill the pipe hole.

7 hub login.

Indoor Model 40MBCQ09---3 40MBCQ12---3 40MBCQ18---3 40MBCQ24---3 ENERGY STAR® YES YES YES NO Cooling System Tons 0.75 1.00 1.33 2.00 Cooling Rated Capacity Btu/h 9,000 12,000 16,000 24,000 Cooling Cap. Range Min - Max Btu/h 2,850~11,100 3,000~13,700 5,600~17,000 8,000~25,000 SEER 20.5 21.5 20.0 20.0 EER 13.0 12.7 12.5 11.0Indoor Model 40MBCQ09---3 40MBCQ12---3 40MBCQ18---3 40MBCQ24---3 40MBCQ36---3 40MBCQ48---3 Electrical Voltage, Phase, Cycle V/Ph/Hz 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 Power Supply Indoor unit powered from outdoor unit Indoor unit powered from outdoor unit MCA A. 0.2 0.2 0.2 0.3 0.8 1.6 Controls38maqb12r--1; 38maqb09r--3 38maqb12r--3: 38maqb18r--3 38maqb24r--3: 38maqb30r--3 38maqb36r--3: 38mbrbq36aa3 38mbrbq48aa3: 38mbrq58a--3 38marbq12xa138marbq06xa3 38marbq09xa3 38marbq12xa3 38marbq18xa3 38marbq24xa3 38marbq30xa3 38marbq36xa3 38marbq36ab3 38mbrcq36aa3 38mbrcq48aa3 38mbrcq58aa3Carrier Enterprise Mid-Atlantic Technical Support Site40MBCQ12---3 - 12000 Btuh Ductless Heat Pump Cassette.

Feb 28, 2024 · Description. The Carrier 38MAQ Mini Split Heat Pump System with Extreme Comfort Performance offer heating down to -22 degrees and cooling up to 130 degrees Fahrenheit. It’s one more way Carrier Ductless systems offer your customers indoor comfort solutions for any space, anytime of year. And with a full line of innovative systems offering a ...OVERVIEW, The 40MBCQ12-3 38MARBQ12AA3 Performance series single zone mini split is a heat pump solution with a ceiling cassette air handler for . Heating Repair Whitehall, PA Heating Contractor In Whiteha;;, PA. Cooling ...Carrier 40MBQB12D--3 Service Manual (42 pages) 40MB*D Ducted Ductless System Sizes 09 to 48. Brand: Carrier | Category: Air Conditioner | Size: 4.75 MB.Temperature/Timer display This display is blank when Displays the set temperature by default, or timer setting set to AUTO speed or DRY mode. when using TIMER ON/OFF functions. Temperature range: 62-86 F. o. Timer setting range: 0-24 hours. This display is blank when operating in FAN mode. Fig. 5 − Unit Display.The document listing is represented by a combination of the UL CCN and File Number. A UL CCN (Category Control Number) is the code that represents the Product Category (Category Description).Features Outdoor: • Connect 2, multiple style indoor units High Wall Cassette Ducted Floor Console • Variable Speed (Inverter) Compressor • Basepan Heater factory installedShop for 12000 BTU Single Zone Mini-Split 208/230V from Carrier Corporation At Ferguson. Ferguson is the #1 US plumbing supply company and a top distributor of HVAC parts, waterworks supplies, and MRO products.Indoor Model 40MBCQ12---3 Energy Star YES Cooling Rated Capacity 12,000 Cooling Cap. Range Min - Max 4,000~13000 SEER Heating Cap. Range Min - Max: 5,000~13500 HSPF: 10.6 COP (47°F) 3.67 Heating Rated Capacity (17°F) 8,700 Heating Maximum Capacity (17°F) 12,0001. Install the Adapter Board and the Display Board on the High Wall (See the Appendix for instructions). 2. Connect the female joint of the wires group from the adapter board with the male joint of the connective wires group. Next, connect the other side of the adapter board with the display board (see Fig. 3).Check pg. 8 of the latest version of "Compatibility Charts" for updates regarding 24V interface incompatibility. The Carrier Infinity™ Ductless systems are shipped with a Wi-Fi kit standard.48,000 BTU 22.4 SEER 5-Zone Heat Pump System 9+9+9+12+12 - Casette. 570DB2AD-1432-4663-A444-7A78C72FD7BD. Out of StockIndoor Model 40MBCQ12---3 Energy Star YES Cooling Rated Capacity 12,000 Cooling Cap. Range Min - Max 3,000~13,700 SEER Heating Cap. Range Min - Max 2,000~15,300 HSPF 10.6 COP (47°F) 3.22 Heating Rated Capacity (17°F) 8,250 Heating Maximum Capacity (17°F) 14,000 Heating Maximum Capacity (5°F)

Controls. Notes: † 7 Day programmable compatible with indoor units starting with Serial Number 0216V10001. ‡ Compatible with indoor units starting with Serial Number 0117V10001. ** Starting with Serial Number 2820V10001 (Week 28, Year 2020) *24V interface compatible with all indoor units starting with Serial Number 4216V10001 unless …

Compatibility Controls. Notes: † 7 Day programmable compatible with indoor units starting with Serial Number 0216V10001. ‡ Compatible with indoor units starting with Serial Number 0117V10001. ** Starting with Serial Number 2820V10001 (Week 28, Year 2020) the KSACN0701AAA became the standard controller but is backwards compatible with ...Sometimes, in order to address a Carrier outdoor unit communication fault, you must reset the heat pump. Turn off the heat pump at the breaker. Make sure that the fuse has not blown. Replace it, if necessary. Check the UI settings – if the settings are inappropriate, the compressor might not engage. Reset the circuit breaker.3 model number nomenclature rbq system type q = heat pump unit type r = outdoor unit not used outdoor unit 38 mg 318 38 = outdoor unit mg = all voltage 3 = 208/230-1-60 nominal capacity 18 - 1 1/2 tons 24 - 2 tons 30 - 2 1/2 tons 36 - 3 tons 48 - 4 tons maximum number of fan coil units thatCompatibility Controls. Notes: † 7 Day programmable compatible with indoor units starting with Serial Number 0216V10001. ‡ Compatible with indoor units starting with Serial Number 0117V10001. ** Starting with Serial Number 2820V10001 (Week 28, Year 2020) the KSACN0701AAA became the standard controller but is backwards compatible with ...619req012cbma 40mbcq12---3 619req018cbma 40mbcq18---3 40mbcq24---3 40mbcaq24xa3 40mbcq36---3 40mbcaq36xa3 40mbcq48---3 40mbcaq48xa3 40mccaq09xa3 40mccaq18xa3 619req009dbma 40mbdq09---3 40mbdaq09xh3 619req012dbma 40mbdq12---3 40mbdaq12xh3 619req018dbma 40mbdq18---3 40mbdaq18xh3 619req024dbma 40mbdq24---3 40mbdaq24xh3We would like to show you a description here but the site won’t allow us.High Wall Heat Pump Ductless System Indoor Model: Job Data: Location: Buyer: Buyer P.O. #: Carrier #: Unit Number: Model Number: Date: 12 Face Area Sq. Ft. 2.1940mbcq12---3 1t hp 230v 1/4x1/2 ceiling cassette 19 seer add grille 40mbcq01xxx3 (40mbqb12c--3) add to cart. 40mbcq24---3 2t hp 230v 5/8x3/8 ceiling cassette 20 seer add grille 40mbcq02xxx3. add to cart. 40mbcq18---3 1.5t hp 230v 1/4x1/2 ceiling cassette 20 seer add grille 40mbcq01xxx3 (40mbqb18d--3)

The slope unblocked game extension.

Best astd units.

Carrier Enterprise Mid-Atlantic Technical Support Site48,000 BTU 22.4 SEER 5-Zone Heat Pump System 9+9+12+12+18 - Casette9.52*3 ) 12.5 R410A Heatin g Rated Ca p acit y (47°F ) Btu/h 23 ,000 Char g e lbs (k g) 6.17 (2.8 ) Heatin g Maximum Ca p acit y (5°F ) Btu/h 23 ,000 EEVCarrier "Outdoor Unit Not Communicating". Hi Guys, I found this forum while searching for a clue as to why my A/C has failed. I gathered as much information as I can from the thermostat display. I had this Carrier Infinity system installed by Sears in 2009, IIRC: - Heat Pump: 25HNA 1 Stage, 48KBTU. - Air Handler: FE4AF0050.Looking for Guide Information documents and more? Product iQ offers professional level information and is free for most users. Join Product iQ. Anyone can obtain information about the validity of a given certification by contacting the UL Customer Experience Center. Phone number: 1-877-854-3577 — Email: [email protected] you have a Carrier Infinity Outdoor Unit with Communication Fault 179, don’t despair! This is a relatively easy problem to fix. First, check the power to the unit. Make sure that the circuit breaker is not tripped and that there is no loose wiring. If everything looks good there, move on to step two.Compatibility Table For matched compatibility see Product Data 40MPHAQ09XA3 40MPHAQ12XA3 40MAQB09B--3 40MAQB12B--3 40MAQB18B--3 40MAQB24B--3 40MAHBQ06XA3 40MAHBQ09XA3 40MAHBQ12XA3 40MAHBQ18XA3 40MAHBQ24XA3Features Outdoor: • Connect up to 4, multiple style indoor units High Wall Cassette Ducted Console • 100% Heating Capacity at 5° F (-15° C) • Variable Speed (Inverter) CompressorShop for 12000 BTU Single Zone Mini-Split 208/230V from Carrier Corporation At Ferguson. Ferguson is the #1 US plumbing supply company and a top distributor of HVAC parts, waterworks supplies, and MRO products.40MBCQ12---3 2 Voltage, Phase, Cycle V/Ph/Hz 208/230-1-60 19 4 MCA A. 0.2 Body Unit Width in (mm) 22.44 (570) Standard Body Unit Height in (mm) 10.24 (260) Optional Body Unit Depth in (mm) 22.44 (570) Cooling Indoor DB Min -Max °F(°C) 63~90 (17~32) Body Net Weight lbs (kg) 35.27 (16)Carrier Enterprise Mid-Atlantic Technical Support Site - Carrier ... ….

Douglas Taylor Air Conditioning & Refrigeration Inc, 6560 116th Ave N, Largo, FL (Owned by: Taylor, Douglas) holds a M Air Conditioning Class A license and 4 other licenses according to the Orange County license board. Their BuildZoom score of 108 ranks in the top 5% of 191,428 Florida licensed contractors. Their license was verified as active ...Versatile Comfort You Can Look Up To. Ideal for a converted space or room addition where ductwork is not available, the Preferred™ Series 40MBCQ Cassette fits comfortably over-head to deliver quiet, unobtrusive heating and cooling. It senses the temperature at your handheld remote to place comfort where you need it most, and provides the ...Carrier mini split is making loud or unusual noises. A rattling sound may indicate something is loose and needs tightening. Check your units for loose bolts and screws. Other noises like buzzing, screeching, or hissing require the attention of a professional. If the noise isn't consistent, record it on your phone to play for your tech.Heating Setback (46° F Heating Mode) Quiet indoor operation, as low 34 decibels 1. Built-in condensate lift pump. Grille/Ceiling Panel 2' x sizes 9 to 3' 48. Aluminum Golden Hydrophilic pre-coated fins. 10-year parts limited and 10-year compressor warranties the original purchasing owner upon timely registration 2.40MBFQ12---3 - Ductless 12,000 Btuh Heat Pump Floor Console (208/230-1-60)40MBCQ12---3. 40MBCQ18---3. 7,540 / 63% 6,890 / 57% 7,160 / 80% 7,320 / 81% 10,472 / 116% KSACN0501A AA. Programmable W ired Wall Mount Controller. Includes 19ft cable / max 66ft . 17317100A11945. Programmable Cooling Only Wired Controller. Includes 19ft cable / max 66ft . Indoor unit includes integrated condensate lift pump. Drain line ...48,000 BTU 22.4 SEER 5-Zone Heat Pump System 9+12+12+12+12 - CasetteIndoor Model 40MBCQ12---3 Energy Star YES Cooling Rated Capacity 12,000 Cooling Cap. Range Min - Max 4,000~13000 SEER Heating Cap. Range Min - Max: 5,000~13500 HSPF: 10.6 COP (47°F) 3.67 Heating Rated Capacity (17°F) 8,700 Heating Maximum Capacity (17°F) 12,000619phaq12xa3: 619peq009bbma 619peq012bbma 619peq018bbma 619req009cbma 619req012cbma 619req018cbma 619req009dbma 619req012dbma 619req018dbma 619req009fbmaIndoor Unit 40MBCQ09---3 40MBCQ12---3 40MBCQ18---3 Outdoor Unit Single Zone 38MAQB09R--3 38MAQB12R--3 38MAQB18R--3 Outdoor Unit Multi-zone 38MGRQ18B--3 38MGRQ24C--3 38MGRQ30D--3 38MGRQ36D--3 38MGRQ48E--3 NOTE: Backward compatible with 38MAQ Single Zone and 38MGQ Multi−zone systems. 40mbcq12, Indoor Unit 40MBCQ09---3 40MBCQ12---3 40MBCQ18---3 Outdoor Unit Single Zone 38MAQB09R--3 38MAQB12R--3 38MAQB18R--3 Outdoor Unit Multi-zone 38MGRQ18B--3 38MGRQ24C--3 38MGRQ30D--3 38MGRQ36D--3 38MGRQ48E--3 NOTE: Backward compatible with 38MAQ Single Zone and 38MGQ Multi−zone systems., Line Length. Additional Charge >25ft. Max. Lift. MCA / MOCP. Recommended Fuse Size. Maximum Maximum Heating BTU's Heating BTU's at -40F at 50F At 69°F Indoor DB. Maximum Maximum Cooling BTU's Cooling BTU's at 1130F at 1220F At 75.2°F Indoor DB. This sheet is not intended to replace the Installation Instructions., 30K Outdoor Ductless HP Multi Zone Performance 208/230V R410A Zone 1 Indoor Model: 12K Cassette Ductless Indoor HP Performance 208/230V R410A, 40mbcq12---3 40mbcq18---3 619phaq09xa3 619phaq12xa3 619peq009bbma dhmshaq09xa3 619peq012bbma dhmshaq12xa3 619peq018bbma dhmshaq18xa3 619ahbq09xa3 dhmahbq09xa3 40mbfq24---3 40mbaaq24xa3 indoor unit high wall dhmphaq09xa3 dhmphaq12xa3 619peq024bbma dhmshaq24xa3 619ahbq06xa3 dhmahbq06xa3 40mhhq09---3 40mhhq12---3 40mhhq18---3 619req012cbma ..., Sizes: 09 / 12 18 24 36 48. Available in 208/230V. Modes: Cool, Heat, Dry, Fan, Auto. Auto-restart function. Louver control (fixed or swing) Three fan speeds. Follow Me (senses temperature at handheld remote) Heating Setback (46° F Heating Mode) Quiet indoor operation, as low 34 decibels 1., Sometimes, in order to address a Carrier outdoor unit communication fault, you must reset the heat pump. Turn off the heat pump at the breaker. Make sure that the fuse has not blown. Replace it, if necessary. Check the UI settings - if the settings are inappropriate, the compressor might not engage. Reset the circuit breaker., Wireless Remote Controller included with indoor unit Optional Wired Remote Controller (Timer Function) Wired Remote Controller KSACN0501AAA (7 Day programmable) included, Carrier Performance"' Console 1:1 Heat Pur Single Zone Quick Reference Guide High Heating Systems - 100% of Rated Capacity @ 50F I Nominal Cooling Capacity @ -130F, Regardless of size, when two (2) AHUs are connected to any MZ ODU, no other indoor units can be added to the system. If a 30k or 36k AHU is connected to a any outdoor unit, 500g (17.6 Oz) of additional refrigerant charge has to be added to the system. 30k or 36k indoor units are not compatilble with phased out models., Modes: Cool, Heat, Dry, Fan, Auto Louver Control (Fixed or Swing) Outside Air Intake Built-in condensate Lift pump Follow Me (senses temperature at handheld remote), The Carrier 40MBCQ12-3 Performance series ceiling cassette air handler is a good all-around choice for any application where a wall mounted option is not feasible. With a built-in condensate lift pump and a standard size to fit between many ceiling supports, this air handler is less expensive and easier to install over similar brands., 48,000 BTU 22.4 SEER 5-Zone Heat Pump System 9+12+12+12+12 - Casette, Displays the set temperature by default, or fan speed or timer setting when using TIMER ON/OFF functions. Temperature range: This fan speed can not be adjusted in AUTO or DRY mode. 62-86°F/17-30°C (20-28°C) (Model dependent) Timer setting range: 0-24 hours This display is blank when operating in FAN mode., Heating & Cooling Basics. Explore the basics of home heating and cooling, ventilation, and air quality, then learn how to choose and maintain your HVAC system., 40MBCQ. Small but mighty, the 40MBCQ Cassette ductless indoor unit works quietly overhead and out of the way, providing efficient heating and cooling. Three fan speeds and a temperature-sensing handheld remote work together to place airflow right where you want it. It’s a convenient, versatile solution for both single and multi-zone systems., Compatibility Controls. Notes: † 7 Day programmable compatible with indoor units starting with Serial Number 0216V10001. ‡ Compatible with indoor units starting with Serial Number 0117V10001. *24V interface compatible with all indoor units starting with Serial Number 4216V10001 unless noted Ͱ 24V Interface compatible with all the sizes ..., 40MBCQ Cassette Ductless System Sizes 09 to 48 Installation Instructions NOTE: The images in this manual are for illustration purposes only. The actual model may differ slightly. NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS, Compatibility Table For matched compatibility see Product Data 40MPHAQ09XA3 40MPHAQ12XA3 40MAQB09B--3 40MAQB12B--3 40MAQB18B--3 40MAQB24B--3 40MAHBQ06XA3 40MAHBQ09XA3 40MAHBQ12XA3 40MAHBQ18XA3 40MAHBQ24XA3, 72,000 to 336,000 Btuh 6.0 to 28.0 Tons. The Carrier 38VMR VRF 2-pipe heat recovery system is a combination of an outdoor unit with multiple style indoor units connected by refrigerant piping and wiring. Heat recovery outdoor unit lineup is a single module up to 28 tons, available as small and medium cabinet size., published as of 12/19. 4. elect models only. Based on Bryant testing. Compared to a single-stage 13.0 S SEER system, in worst-case conditions (cool and damp)., 48,000 BTU 22.4 SEER 4-Zone Heat Pump System 9+9+12+18 - Casette. CE977F76-BEBF-4FF7-BE06-BA94F10BFFB4. Out of Stock, 36,000 BTU 21.5 SEER 4-Zone Heat Pump System 9+12+18+18 - Casette, Looking for Guide Information documents and more? Product iQ offers professional level information and is free for most users. Join Product iQ. Anyone can obtain information about the validity of a given certification by contacting the UL Customer Experience Center. Phone number: 1-877-854-3577 — Email: [email protected]., Sometimes, in order to address a Carrier outdoor unit communication fault, you must reset the heat pump. Turn off the heat pump at the breaker. Make sure that the fuse has not blown. Replace it, if necessary. Check the UI settings – if the settings are inappropriate, the compressor might not engage. Reset the circuit breaker., cool or warm your home with a bryant ® heat pump bryant offers real choices for efficient and reliable home comfort bryant.com, PERFORMANCE™ SERIES 38MGR OUTDOOR UNIT PERFORMANCE: Non-Ducted Size 18 24 30 36 48 Outdoor Model 38MGRQ18B--3 38MGRQ24C--3 38MGRQ30D--3 38MGRQ36D--3 38MGRQ48E--3, 40MBCQ12---3 40MBCQ18---3 619REQ012CBMA 619REQ018CBMA 619REQ009DBMA 619REQ012DBMA 619REQ018DBMA 619PEQ024BBMA DHMSHAQ24XA3 38MGRQ36D--3 Submittal Data MULTI-ZONE STANDARD FEATURES Features Outdoor: • Connect up to 4, multiple style indoor units High Wall Cassette Ducted Console Air Handler • 100% Heating Capacity at 5° F (-15° C), Download this manual. 40MBCQ. Cassette Ductless System. Sizes 09 to 48. NOTE: The images in this manual are for illustration purposes. only. The actual model may differ slightly. NOTE: Read the entire instruction manual before starting the. installation., Whatever the Challenge or Need, Ductless Technology Is the Solution Often called “mini-splits,” ductless systems use the same process for heating and cooling, 30,000 BTU 23.8 SEER 4-Zone Heat Pump System 9+9+9+12 - Casette. 3CC1700B-0A3E-41B1-9D1D-4D8A4B21F00E. Out of Stock, STANDARD FEATURES. Modes: Cool, Heat, Dry, Fan, Auto. Timer. Louver Control (Fixed or Swing) Built in Condensate Lift Pump. Follow me. 46°F Heating Mode (Heating Setback) Aluminum Blue Hydrophilic pre-coated fins., Optional. Standard. Notes: † 7 Day programmable compatible with indoor units starting with Serial Number 0216V10001. ‡ Compatible with indoor units starting with Serial Number 0117V10001. ** Starting with Serial Number 2820V10001 (Week 28, Year 2020) the KSACN0701AAA became the standard controller but is backwards compatible with …, DIY steps of installing a 4-way ceiling type cassette heat pump / AC in an old house attic.